Panelboards and over-current protection devices (circuit breakers and fuses)
Service grounding and bonding
A representative number of switches, lighting fixtures and receptacles, including receptacles observed and deemed to be AFCI protected using the test button
All ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs using tester
For the presence of smoker and carbon-monoxide detectors
The inspection report shall include:
Main service disconnect's amperage rating, if labeled
Type of wiring observed
Condition of items inspected above
Any deficiencies in the integrity of the service-entrance conductor's insulation, drip loop and vertical clearances from grade and roofs
Any unused circuit-breaker panel opening that was not filled
Any presence of solid conductor aluminum branch-circuit wiring, if visible
Any tested receptacle in which power was not present, polarity was incorrect, cover was not in place, GFCI devices not properly installed or did not operate properly, evidence arcing or excessive heat and where the receptacle was not grounded or was not secured to the wall